Clinical-use limitation. This independently prepared document is an educational prescribing framework, not an official VitroSorb document, a device IFU, or a patient-specific order. Only SECORIM® ABO plasma immunoadsorption columns are within scope. Confirm the current, market-specific instructions for use, compatible plasma separator, approvals, column orientation, priming, alarms, access, anticoagulation and flow limits before any treatment. Transplant decisions require a specialist multidisciplinary team.

Scope and therapeutic objectives

SECORIM® ABO is a selective plasma immunoadsorption device. In an extracorporeal apheresis circuit, plasma is separated from cellular components, passed through a column bearing synthetic blood group A/B carbohydrate ligands, and then returned together with the blood cells. The objective is selective removal of recipient anti-A and/or anti-B isoagglutinins in ABO-incompatible transplantation.

Plasma separation requiredSingle-use adsorbersAnti-A / anti-B specificitySpecialist transplant pathway
  • Reduce donor-directed ABO antibody titers before a planned ABO-incompatible graft.
  • Support desensitization alongside separately prescribed immunosuppression and transplantation protocols.
  • Preserve more non-target plasma constituents than broad plasma replacement methods, while recognizing that some procedural losses and complications remain possible.
Clinical evidence: Most SECORIM®-specific data arise from case reports or small observational cohorts, not randomized comparative trials. A fall in antibody titer is a surrogate endpoint; graft outcomes depend on the entire transplant protocol. [1,4–7]

SECORIM® ABO plasma adsorber selection

Donor ABO groupRecipient ABO groupPlasma column to considerTarget antibody
AO or BSECORIM® AAnti-A
BO or ASECORIM® BAnti-B
ABASECORIM® BAnti-B
ABBSECORIM® AAnti-A
ABOSECORIM® ABAnti-A and anti-B
Donor/recipient selection table follows the VitroSorb manufacturer brochure. Final choice must be confirmed against the immunohematology report and current IFU. [2]

Manufacturer brochure specifications (2023; verify current IFU)

CharacteristicPublished specificationInterpretation
Column housing volume70 mLManufacturer brochure, not the extracorporeal circuit volume
Priming volume34 mLBrochure value; use current IFU for priming steps
MatrixPolymethacrylate with synthetic oligosaccharidesABO-specific binding ligands
ConnectorsMale / female Luer lockConfirm validated tubing and line compatibility
LabelingSingle-use; electron-beam sterilizedDo not reprocess or reuse unless a current authorized IFU explicitly permits it
Storage in 2023 brochure+5°C to +25°CCheck current packaging label, expiry and regional IFU

These are product-identification data, not authorization to operate a column without the complete instructions for use. [2,3]

Patient selection and treatment goals

Principal documented application

Pre-transplant desensitization in ABO-incompatible living-donor kidney transplantation, as a part of a coordinated transplant-center protocol.

Primary endpoint: reduction of recipient anti-donor A/B IgG and/or IgM titers to the center-defined threshold.

Other clinical scenarios

Some reports and manufacturer information discuss selected ABO-incompatible nonrenal transplant indications and antibody-mediated complications. These require indication-specific evidence review, multidisciplinary approval and regional authorization; do not generalize the kidney protocol.

Document the proposed donor/recipient ABO pairing, planned transplantation date, baseline titer method, sensitization history, immunosuppressive strategy, alternative procedures, expected benefits and predefined stopping rules.

Example of a published threshold: A 2025 SECORIM® kidney transplant cohort described reduction of pre-transplant IgG isoagglutinin titers to ≤1:8 before transplantation. This is a study-specific center target, not a universal device threshold. Laboratory titer methods are not directly interchangeable. [4]

Plasma-only treatment pathway

Patient blood→Plasma separation→Plasma pump→SECORIM® A / B / AB→Treated plasma + blood cells→Patient return

The SECORIM® column treats the separated plasma branch. Blood cells bypass the adsorber and recombine with the treated plasma before returning to the patient. The treatment is plasma adsorption, not therapeutic plasma exchange: plasma is generally returned rather than discarded.

  • Use an approved plasma-separation method (centrifugal or membrane-based) with an authorized, compatible circuit.
  • Confirm pressure monitoring, air detection, access pressures, flow stability, reconnection and air removal according to the device IFUs.
  • Replacement solution is not routinely required in the same manner as TPE, but prescribe extracorporeal volume, rinsing/displacement, losses and fluid balance as appropriate.

Prescription variables and documented examples

VariableDocumented examplePrescribing requirement
Plasma flow through adsorber20–70 mL/min in the 2023 brochureBrochure information, not an automatic setting; follow current IFU and clinical tolerance [2]
Plasma flow in published clinical cohorts20–50 mL/min in one published series; 40–50 mL/min in anotherStudy context only; do not transfer settings to other separators [5,6]
Blood flow / plasma separationVaries considerably with technique and vascular accessSpecify using the separator IFU, hematocrit and permitted extraction limits
Processed plasma per sessionStudy-dependent; one series described approximately 2.5–3.0 LUse an individualized target; processed ≠ exchanged plasma [5]
Session duration / frequencyVariable in institutional reportsSet by target titer, clinical response, planned transplant timing, safety and IFU capacity
AnticoagulationACD-A or heparin named in manufacturer brochureAgent, dosing, calcium plan and monitoring require an approved device-specific protocol [2]
Column useManufacturer/supplier states sterile, single-useNew column for each procedure; research descriptions of reuse are not IFU guidance [3]
Do not confuse: the plasma processed through the immunoadsorber with the amount removed from circulation or exchanged with replacement fluid. Published flow and plasma-volume numbers do not constitute validated universal prescriptions.

Plasma volume and processing estimator

Estimates a patient's plasma volume and the amount of plasma circulated through SECORIM® using selected flow and session duration. It does not determine the necessary antibody removal, session count, or approved device settings.

Estimated patient plasma volume—
Plasma processed through column—
Processed plasma / patient EPV—
EPV (L) ≈ 0.065 × weight (kg) × (1 − hematocrit fraction)
Processed plasma (L) = plasma flow (mL/min) × duration (min) ÷ 1,000

Educational estimate. Calculations are not a dose recommendation.

ABO antibody reduction and scheduling

  • Establish recipient anti-donor IgG and IgM isoagglutinin titers using a consistent validated laboratory method. Document which titer is driving decisions.
  • Coordinate session timing with the transplant and immunology teams; repeat measurements before/after procedures and as required by the center to detect antibody rebound.
  • Define the center's pre-transplant titer threshold and whether a rescue plan (additional immunoadsorption or alternative apheresis) is required.
  • Immunosuppression, infection prevention and post-transplant monitoring are separate clinician-prescribed pathways and should not be inferred from column specifications.
  • Proceed only when the overall immunologic and clinical criteria for transplantation are met.
Evidence: A 21-person observational series reported 1–3 SECORIM® sessions and a pre-transplant target of ≤1:8; this does not define how many sessions any specific patient needs. [4]

Preparation, anticoagulation and vascular access

Pre-session device checks
  • Correct A, B or AB column for donor/recipient pairing
  • Exact model / expiry / sterile package integrity
  • Approved separator, tubing and pressure sensors
  • Current IFU: mounting orientation, priming and flushing
  • Extracorporeal blood volume and fluid balance
Anticoagulation plan
  • Document approved agent and individual protocol
  • Account for bleeding risk, thrombocytopenia and HIT history
  • When citrate is used: symptom surveillance and ionized calcium plan
  • Monitor access and circuit pressures and clotting signs
  • Adjust only according to locally authorized procedures

Vascular access may be peripheral or central depending on apheresis technology, clinical factors and achievable flow. Avoid arbitrary citrate ratios or heparin dosing from unrelated devices.

Pre-treatment, intraprocedural and follow-up assessment

StageRequired documentation
Before a courseRecipient/donor ABO groups; indication; titer method and baseline anti-donor IgG/IgM; transplant protocol; consent; access assessment; relevant infection/immunosuppression status
Before each sessionClinical status, blood pressure, weight/fluid balance; CBC/platelets; renal function and electrolytes; calcium/coagulation as appropriate; current antibody titers; compatible consumables
DuringHemodynamics and symptoms; blood/plasma flow; plasma-separator and adsorber pressures; air/clotting alarms; anticoagulation tolerance; fluid balance
After each sessionTreatment volume, duration and tolerance; isoagglutinin titers at a pre-defined time point; access/bleeding complications; immediate clinical response
Across transplant courseTiter rebound, transplant readiness, graft function, evidence of rejection, infection and immunosuppression complications, need to repeat or stop treatment

Risks, contraindication checks and escalation

Potential procedural risks
  • Hypotension or vasovagal symptoms
  • Allergic or biocompatibility reaction
  • Access bleeding, infection or thrombosis
  • Clotting, pressure rise or air alarm
  • Anticoagulant-related bleeding or citrate hypocalcemia
  • Inadequate titer reduction or rebound
Pause, stop or escalate according to protocol
  • Persistent hemodynamic instability
  • Severe hypersensitivity, bleeding or suspected hemolysis
  • Unresolved pressure, air or clotting alarms
  • Unacceptable laboratory abnormality
  • Insufficient antibody response or loss of clinical benefit
  • Deviation from IFU conditions or device safety limits

Review all current IFU contraindications and warnings. This summary cannot establish patient-specific contraindications or override a specialist's treatment decision.

SECORIM® ABO prescription checklist

For clinical documentation support only. An authorized clinician must review all patient-specific orders.

Prescription Worksheet — Complete & Print

Fill in this patient-specific prescription worksheet on screen, copy the completed fields, or print the worksheet alone. Blank fields are intentional; the worksheet does not determine appropriate device settings or constitute an authorized medical order.

Prescription fieldClinician entry / verification
Patient & clinical indication
Patient identifier / hospital record
Treatment date / time
Clinical service / prescribing physician
Diagnosis / indication
Therapeutic objective / response criteria
Device & patient assessment
Exact product / modality
Product lot / IFU revision / local authorization
Device platform, separator and extracorporeal circuit
Vascular access
Weight / hematocrit / estimated plasma volume
Treatment prescription
Blood flow and plasma flow
Processed plasma target / treatment volume
Planned duration and treatment frequency
Procedure-specific details
Donor and recipient ABO groups
Anti-A / anti-B IgG and IgM titers
Transplant / intervention schedule
SECORIM specificity / single-use verification
Safety, monitoring & authorization
Priming, fluid return and balance
Anticoagulant regimen and monitoring
Medication review / contraindications
Baseline and procedural monitoring
Stopping / escalation criteria
Consent / physician validation / signature

Mandatory clinical verification: the signed institutional order, current model-specific manufacturer IFU, applicable regulatory authorization and patient-specific medical review take precedence. The worksheet remains entirely local to this page; its entries are not saved or transmitted.

Evidence and source limitations

  1. VitroSorb — SECORIM® ABO product page. Manufacturer overview and plasma-circuit concept.
  2. VitroSorb SECORIM® ABO brochure (15 Jun 2023). Product selection table, plasma flow and reported specifications. Marketing brochure not a complete current IFU.
  3. Stark Medical — VitroSorb SECORIM® ABO. Distributor statement of intended use and single-use status.
  4. Kalra V, Roy A, Gupta U, Khaira A (2025). SECORIM®-ABO desensitization in 21 ABO-incompatible living-donor kidney transplant recipients; small observational cohort.
  5. Immunoadsorption-Based Desensitization With Column Reuse in ABO-Incompatible Living Donor Renal Transplantation. Published technical parameters; reports reuse, which conflicts with single-use labeling and is not recommended here.
  6. Clinical Evidence of Immunoadsorption Column for Desensitization in ABO-incompatible Renal Transplantation (2023). Case series; heterogeneous study procedures, not official IFU instructions.
  7. Enhancing Success in the ABO-Incompatible Kidney Transplantation: A Case Report (2024). Illustrative individual-case evidence.
  8. British Society for Haematology (2025): Apheresis procedures for the treatment of patients. General apheresis care and planning guidance; not a SECORIM-specific protocol.
  9. American Society for Apheresis (2026): Tenth Special Issue. Broad therapeutic apheresis recommendations; use indication-specific fact sheets where applicable.
Evidence hierarchy: current, locally applicable SECORIM® IFU and regulatory status → transplant-center protocol → disease-specific society guidance → peer-reviewed clinical data → manufacturer brochures. Brochure numbers and case-series settings are explicitly not universal prescriptions.