Scope and therapeutic objectives
SECORIM® ABO is a selective plasma immunoadsorption device. In an extracorporeal apheresis circuit, plasma is separated from cellular components, passed through a column bearing synthetic blood group A/B carbohydrate ligands, and then returned together with the blood cells. The objective is selective removal of recipient anti-A and/or anti-B isoagglutinins in ABO-incompatible transplantation.
- Reduce donor-directed ABO antibody titers before a planned ABO-incompatible graft.
- Support desensitization alongside separately prescribed immunosuppression and transplantation protocols.
- Preserve more non-target plasma constituents than broad plasma replacement methods, while recognizing that some procedural losses and complications remain possible.
SECORIM® ABO plasma adsorber selection
| Donor ABO group | Recipient ABO group | Plasma column to consider | Target antibody |
|---|---|---|---|
| A | O or B | SECORIM® A | Anti-A |
| B | O or A | SECORIM® B | Anti-B |
| AB | A | SECORIM® B | Anti-B |
| AB | B | SECORIM® A | Anti-A |
| AB | O | SECORIM® AB | Anti-A and anti-B |
Manufacturer brochure specifications (2023; verify current IFU)
| Characteristic | Published specification | Interpretation |
|---|---|---|
| Column housing volume | 70 mL | Manufacturer brochure, not the extracorporeal circuit volume |
| Priming volume | 34 mL | Brochure value; use current IFU for priming steps |
| Matrix | Polymethacrylate with synthetic oligosaccharides | ABO-specific binding ligands |
| Connectors | Male / female Luer lock | Confirm validated tubing and line compatibility |
| Labeling | Single-use; electron-beam sterilized | Do not reprocess or reuse unless a current authorized IFU explicitly permits it |
| Storage in 2023 brochure | +5°C to +25°C | Check current packaging label, expiry and regional IFU |
These are product-identification data, not authorization to operate a column without the complete instructions for use. [2,3]
Patient selection and treatment goals
Pre-transplant desensitization in ABO-incompatible living-donor kidney transplantation, as a part of a coordinated transplant-center protocol.
Primary endpoint: reduction of recipient anti-donor A/B IgG and/or IgM titers to the center-defined threshold.
Some reports and manufacturer information discuss selected ABO-incompatible nonrenal transplant indications and antibody-mediated complications. These require indication-specific evidence review, multidisciplinary approval and regional authorization; do not generalize the kidney protocol.
Document the proposed donor/recipient ABO pairing, planned transplantation date, baseline titer method, sensitization history, immunosuppressive strategy, alternative procedures, expected benefits and predefined stopping rules.
Plasma-only treatment pathway
The SECORIM® column treats the separated plasma branch. Blood cells bypass the adsorber and recombine with the treated plasma before returning to the patient. The treatment is plasma adsorption, not therapeutic plasma exchange: plasma is generally returned rather than discarded.
- Use an approved plasma-separation method (centrifugal or membrane-based) with an authorized, compatible circuit.
- Confirm pressure monitoring, air detection, access pressures, flow stability, reconnection and air removal according to the device IFUs.
- Replacement solution is not routinely required in the same manner as TPE, but prescribe extracorporeal volume, rinsing/displacement, losses and fluid balance as appropriate.
Prescription variables and documented examples
| Variable | Documented example | Prescribing requirement |
|---|---|---|
| Plasma flow through adsorber | 20–70 mL/min in the 2023 brochure | Brochure information, not an automatic setting; follow current IFU and clinical tolerance [2] |
| Plasma flow in published clinical cohorts | 20–50 mL/min in one published series; 40–50 mL/min in another | Study context only; do not transfer settings to other separators [5,6] |
| Blood flow / plasma separation | Varies considerably with technique and vascular access | Specify using the separator IFU, hematocrit and permitted extraction limits |
| Processed plasma per session | Study-dependent; one series described approximately 2.5–3.0 L | Use an individualized target; processed ≠ exchanged plasma [5] |
| Session duration / frequency | Variable in institutional reports | Set by target titer, clinical response, planned transplant timing, safety and IFU capacity |
| Anticoagulation | ACD-A or heparin named in manufacturer brochure | Agent, dosing, calcium plan and monitoring require an approved device-specific protocol [2] |
| Column use | Manufacturer/supplier states sterile, single-use | New column for each procedure; research descriptions of reuse are not IFU guidance [3] |
Plasma volume and processing estimator
Estimates a patient's plasma volume and the amount of plasma circulated through SECORIM® using selected flow and session duration. It does not determine the necessary antibody removal, session count, or approved device settings.
Processed plasma (L) = plasma flow (mL/min) × duration (min) ÷ 1,000
Educational estimate. Calculations are not a dose recommendation.
ABO antibody reduction and scheduling
- Establish recipient anti-donor IgG and IgM isoagglutinin titers using a consistent validated laboratory method. Document which titer is driving decisions.
- Coordinate session timing with the transplant and immunology teams; repeat measurements before/after procedures and as required by the center to detect antibody rebound.
- Define the center's pre-transplant titer threshold and whether a rescue plan (additional immunoadsorption or alternative apheresis) is required.
- Immunosuppression, infection prevention and post-transplant monitoring are separate clinician-prescribed pathways and should not be inferred from column specifications.
- Proceed only when the overall immunologic and clinical criteria for transplantation are met.
Preparation, anticoagulation and vascular access
- Correct A, B or AB column for donor/recipient pairing
- Exact model / expiry / sterile package integrity
- Approved separator, tubing and pressure sensors
- Current IFU: mounting orientation, priming and flushing
- Extracorporeal blood volume and fluid balance
- Document approved agent and individual protocol
- Account for bleeding risk, thrombocytopenia and HIT history
- When citrate is used: symptom surveillance and ionized calcium plan
- Monitor access and circuit pressures and clotting signs
- Adjust only according to locally authorized procedures
Vascular access may be peripheral or central depending on apheresis technology, clinical factors and achievable flow. Avoid arbitrary citrate ratios or heparin dosing from unrelated devices.
Pre-treatment, intraprocedural and follow-up assessment
| Stage | Required documentation |
|---|---|
| Before a course | Recipient/donor ABO groups; indication; titer method and baseline anti-donor IgG/IgM; transplant protocol; consent; access assessment; relevant infection/immunosuppression status |
| Before each session | Clinical status, blood pressure, weight/fluid balance; CBC/platelets; renal function and electrolytes; calcium/coagulation as appropriate; current antibody titers; compatible consumables |
| During | Hemodynamics and symptoms; blood/plasma flow; plasma-separator and adsorber pressures; air/clotting alarms; anticoagulation tolerance; fluid balance |
| After each session | Treatment volume, duration and tolerance; isoagglutinin titers at a pre-defined time point; access/bleeding complications; immediate clinical response |
| Across transplant course | Titer rebound, transplant readiness, graft function, evidence of rejection, infection and immunosuppression complications, need to repeat or stop treatment |
Risks, contraindication checks and escalation
- Hypotension or vasovagal symptoms
- Allergic or biocompatibility reaction
- Access bleeding, infection or thrombosis
- Clotting, pressure rise or air alarm
- Anticoagulant-related bleeding or citrate hypocalcemia
- Inadequate titer reduction or rebound
- Persistent hemodynamic instability
- Severe hypersensitivity, bleeding or suspected hemolysis
- Unresolved pressure, air or clotting alarms
- Unacceptable laboratory abnormality
- Insufficient antibody response or loss of clinical benefit
- Deviation from IFU conditions or device safety limits
Review all current IFU contraindications and warnings. This summary cannot establish patient-specific contraindications or override a specialist's treatment decision.
SECORIM® ABO prescription checklist
For clinical documentation support only. An authorized clinician must review all patient-specific orders.
Prescription Worksheet — Complete & Print
Fill in this patient-specific prescription worksheet on screen, copy the completed fields, or print the worksheet alone. Blank fields are intentional; the worksheet does not determine appropriate device settings or constitute an authorized medical order.
Mandatory clinical verification: the signed institutional order, current model-specific manufacturer IFU, applicable regulatory authorization and patient-specific medical review take precedence. The worksheet remains entirely local to this page; its entries are not saved or transmitted.
Evidence and source limitations
- VitroSorb — SECORIM® ABO product page. Manufacturer overview and plasma-circuit concept.
- VitroSorb SECORIM® ABO brochure (15 Jun 2023). Product selection table, plasma flow and reported specifications. Marketing brochure not a complete current IFU.
- Stark Medical — VitroSorb SECORIM® ABO. Distributor statement of intended use and single-use status.
- Kalra V, Roy A, Gupta U, Khaira A (2025). SECORIM®-ABO desensitization in 21 ABO-incompatible living-donor kidney transplant recipients; small observational cohort.
- Immunoadsorption-Based Desensitization With Column Reuse in ABO-Incompatible Living Donor Renal Transplantation. Published technical parameters; reports reuse, which conflicts with single-use labeling and is not recommended here.
- Clinical Evidence of Immunoadsorption Column for Desensitization in ABO-incompatible Renal Transplantation (2023). Case series; heterogeneous study procedures, not official IFU instructions.
- Enhancing Success in the ABO-Incompatible Kidney Transplantation: A Case Report (2024). Illustrative individual-case evidence.
- British Society for Haematology (2025): Apheresis procedures for the treatment of patients. General apheresis care and planning guidance; not a SECORIM-specific protocol.
- American Society for Apheresis (2026): Tenth Special Issue. Broad therapeutic apheresis recommendations; use indication-specific fact sheets where applicable.