Scope, method and evidence boundaries
Plasma adsorption (PA) separates plasma from blood cells, directs plasma across a target-specific adsorbent and reinfuses the processed plasma with blood cells. The plasma is processed, not routinely discarded and replaced as in therapeutic plasma exchange (TPE). Therapy must be matched to the patient's disease, target molecule, technical constraints and local authorizations.
Not included: non-adsorptive plasma separators, plasma-exchange replacement consumables and adsorbers whose current primary product labeling specifies direct whole-blood hemoperfusion rather than a documented plasma indication. No whole-blood treatment setpoints are provided here.
Plasma adsorber catalogue and clinical targets
ImmunoCore®
Plasma immunoadsorber with an immobilized synthetic ligand binding immunoglobulins/autoantibodies and circulating immune complexes.
300 mL housing · single-use · [2,7]
Immuno-Adsopak®
Plasma immunoadsorber for immunoglobulins, autoantibodies and immune complexes; reusable only within the stated same-patient protocol.
300 mL housing · manufacturer lists 5 uses · [3,7]
ABO Adsopak® A / B / AB
Synthetic A/B-antigen-mimetic ligands selectively bind anti-A, anti-B or both anti-A and anti-B isoagglutinins.
A, B, AB variants · size/use rules vary · [4,8]
Lipopak®
Selective plasma adsorption of atherogenic lipoproteins, notably LDL and Lp(a), via an immobilized ligand.
300 mL housing · up to 18 regeneration cycles claimed · [5]
NucleoCore®
Designed to capture extracellular/cell-free DNA and associated DNA-containing structures, including NET-related materials, from plasma.
50 mL / 150 mL housing · single-use · [6]
Exact model matters
Do not substitute a broad Ig sorbent for an antigen-specific ABO column, or a lipoprotein adsorber for an anti-DNA column. Ask the supplier for the exact product code, IFU revision and local regulatory documentation.
Country-specific market checks are mandatory
| Plasma sorbent | Binding target | Plasma-route clinical application | Reuse class / check |
|---|---|---|---|
| ImmunoCore® | Ig / autoantibodies / circulating immune complexes | Specialist Ig immunoadsorption in antibody-mediated disease or transplant rejection protocols | Single-use; check exact IFU [2] |
| Immuno-Adsopak® | Ig / autoantibodies / immune complexes | Multi-session or twin-column immunoadsorption (when specifically validated) | Regenerable, same patient only; detailed handling per IFU [3,7] |
| ABO Adsopak® A | Anti-A isoagglutinins | ABO-incompatible organ transplant pathway when anti-A must be reduced | Specific variant and size determine reuse [4,8] |
| ABO Adsopak® B | Anti-B isoagglutinins | ABO-incompatible organ transplant pathway when anti-B must be reduced | Specific variant and size determine reuse [4,8] |
| ABO Adsopak® AB | Anti-A and anti-B isoagglutinins | When both isoagglutinins require removal in a documented protocol | Specific variant and size determine reuse [4,8] |
| Lipopak® | LDL and Lp(a) / atherogenic lipoproteins | Refractory severe lipid disorders, specialist LDL/Lp(a) apheresis | Regenerable; cycle number is not session number [5] |
| NucleoCore® | Cell-free DNA and DNA-containing structures / NET-related material | Investigational or locally authorized cfDNA-removal pathway; not a routine established disease indication | Single-use; evidence and authorization review required [6] |
ABO Adsopak sizes and antibody matching
Choose the A/B/AB ligand based on the recipient's clinically relevant antibody specificity against donor antigens, with laboratory transfusion/transplant review. A model letter describes the antibody removed, not simply the patient's blood group.
| Model family | Removes | Sizes identified in the manufacturer February 2026 brochure | Handling information from that brochure |
|---|---|---|---|
| ABO Adsopak–A | Anti-A antibodies | A50 · A150 · A300 | 50 mL variant listed as single-use; 150 / 300 mL versions described as patient-specific reusable |
| ABO Adsopak–B | Anti-B antibodies | B50 · B150 · B300 | 50 mL variant listed as single-use; 150 / 300 mL versions described as patient-specific reusable |
| ABO Adsopak–AB | Anti-A and anti-B antibodies | AB50 · AB300 | 50 mL variant listed as single-use; 300 mL version described as patient-specific reusable |
Confirm donor/recipient ABO types, baseline anti-A/anti-B IgG and IgM titers using a consistent laboratory method, desensitization drugs, organ-transplant protocol and the required target titer.
Retest clinically relevant isoagglutinin titers, assess rebound, coordinate transplantation timing and define thresholds for repeat adsorption, change of modality or stopping. No universal target titer applies.
Clinical applications and response measures
POCARD describes immune-mediated neurologic disorders, systemic autoimmune disease and antibody-mediated graft rejection among potential use cases. Select indications only after specialist and guideline review; catalogue examples do not establish the same evidence category for each diagnosis.
Endpoints: organ function, symptoms or disease activity; disease-relevant antibodies (e.g., donor-specific antibodies) when interpretable; total Ig for safety. [2,3,7]
Pre-/post-transplant ABO-incompatible organ pathways; other manufacturer-described ABO antibody indications require a separately justified clinical protocol.
Endpoints: anti-A/anti-B isoagglutinin titers, rebound, graft function and coordinated transplant timing. [4,8]
Severe familial hypercholesterolemia or progressive cardiovascular disease with elevated Lp(a) despite optimized standard measures, according to local lipoprotein-apheresis eligibility rules.
Endpoints: pre-/post-session LDL-C and Lp(a), inter-session rebound, long-term ASCVD course and vascular-access tolerance. [5,9]
Aims to adsorb cfDNA/DNA-associated structures implicated in inflammatory and thromboinflammatory disease processes. Mechanistic rationale does not establish routine treatment benefit for sepsis, transplantation, autoimmune disease or oncology.
Endpoints: protocol-defined cfDNA/NET assay and clinical safety outcomes; ethical/regulatory research review where required. [6]
Before every course, record diagnosis, indication strength, failed/available alternatives, patient consent, expected measurable response, a treatment-frequency rationale and discontinuation criteria. Consult disease-specific guidance, local formulary and the actual IFU.
Separated-plasma pathway and regeneration
Conceptual single-column configuration
The cellular fraction must bypass the plasma adsorber. Use suitable safeguards for air, pressure, leakage, plasma separation quality, temperature and fluid balance. This is a conceptual illustration, not a validated plumbing schematic. [7,8]
Regenerable systems — concept only
Machine names or conceptual examples mentioned in brochures do not prove that a specific combination is currently approved in the user's country or with the installed console version.
Technical inputs and published manufacturer examples
| Parameter | What the clinician records | Source-derived boundary / warning |
|---|---|---|
| Blood flow (Qb) | Set according to access, patient stability and separator | No universal POCARD plasma-adsorption blood flow demonstrated for all product families. |
| Plasma flow (Qp) | Set by separator extraction fraction, filtration safety and adsorber IFU | POCARD's 2026 transplantation brochure describes ≤60 mL/min for ImmunoCore. This is not a default for other columns. [8] |
| Processed plasma (L) | Target volume routed through adsorber | The brochure gives ABO Adsopak study/protocol examples around 3–3.5 L per cycle, with multi-cycle cases; not a blanket patient prescription. [8] |
| Treatment time | Planned minutes and independent safety stopping conditions | Calculated from valid Qp and target volume, not from sorbent volume alone. |
| Session number / frequency | Indication-specific course and laboratory reassessment plan | Manufacturer transplant brochure illustrates a multi-session schedule. Do not extrapolate it to every disease or column. [8] |
| Regeneration/reuse | Exact model, patient assignment, cycle counter and IFU | ImmunoCore and NucleoCore single-use; Immuno-Adsopak, larger ABO Adsopak and Lipopak have model-specific reuse claims. [2–8] |
| Priming | Full circuit and cartridge dead space, priming solution and disposal | Exact prime/rinse, orientation and extracorporeal volume: current IFU only. |
| Anticoagulation | Drug, route, dose, lab monitoring and rescue plan | No cross-family universal anticoagulant regimen; citrate in impaired metabolism needs particular monitoring. |
Processed plasma volume & approximate EPV
Calculate the volume of plasma passing through the adsorber. The optionally estimated plasma volume (EPV) is a rough physiologic reference, not a proprietary POCARD treatment dose. These figures do not estimate sorbent capacity or target removal.
Before connection and at initiation
- Eligibility: confirm disease indication and evidence, exact SKU and local legal authorization, consent, vascular access, current IFU and system/consumable compatibility.
- Preparation: inspect outer packaging, seal, expiry, storage conditions, patient-assignment record, column orientation and documented priming method. Do not substitute unvalidated solutions.
- Plasma quality: verify separation performance, pressure limits, and a circuit that prevents cellular blood from entering a plasma-only column.
- Regenerable column: document patient identity, number of cycles/uses, previous handling, storage/traceability and functional release criteria; never share a regenerated column between patients.
- Anticoagulation: prescribe per machine/column/center protocol, bleeding risk, coagulation profile and drug contraindications. With regional citrate, monitor ionized calcium and acid–base status; verify whether the system supports it.
- Medication review: identify therapies potentially removed during adsorption (including Ig therapeutics/IVIG or other protein-bound treatments) and coordinate doses with pharmacy. Check all product-specific drug interaction and warning sections.
- Circulatory plan: account for full extracorporeal volume, priming/rinse fluid, potential hemodilution, losses and need for any separately ordered replacement strategy.
Baseline, intraprocedural and post-session checks
| When | Core surveillance | Target-specific measurements |
|---|---|---|
| Pre-treatment | Vitals, access check, volume status, CBC/platelets, electrolytes, kidney function, coagulation where relevant; bleeding/infection evaluation | IgG/IgM/IgA and relevant antibodies (Ig sorbents); anti-A/anti-B titers (ABO); LDL-C/Lp(a) (Lipopak); research-validated cfDNA/NETs endpoints if used (NucleoCore) |
| During session | Blood pressure, symptoms, flow, pressures, clots, air detectors, fluid balance, anticoagulation and calcium if indicated | Selected repeat titers or functional adsorption assessment only when protocol-specified; do not interpret surrogate changes in isolation |
| End of session | Hemodynamic tolerance, bleeding/hemolysis signs, recovery of circuit blood, relevant lab reassessment and column disposition | Pre/post target reduction and possible unintended Ig/protein change, consistent with local testing methodology |
| Between sessions | Response, infection risk and hypogammaglobulinemia, renal/hepatic/organ recovery, access patency, treatment harms | Antibody rebound (Ig/ABO), inter-session lipid rebound (Lipopak), protocol-defined endpoints (NucleoCore) |
Document frequency of labs and target-response criteria in the patient-specific order. For recurrent Ig adsorption, consider infection susceptibility and Ig depletion. For ABO procedures, coordinate tightly with the transplant center and transfusion laboratory.
Complications, stopping rules and evidence caveats
- Hypotension, vasovagal reaction and fluid shifts
- Access-site bleeding, infection or thrombosis
- Plasma separator malfunction, clotting or pressure alarms
- Allergy or biocompatibility reaction
- Bleeding or electrolyte changes from anticoagulation
- Potential protein/Ig loss and drug adsorption
- Uncontrolled hypotension, bleeding or severe hypersensitivity
- Persistent critical pressure, air, leak or clotting alarms
- Clinically important hemolysis or laboratory deterioration
- Evidence of regeneration/rinse-fluid crossover
- Loss of safe vascular access or anticoagulation control
- Clinical goals no longer justify risk
Evidence maturity: selective anti-A/B adsorption and lipoprotein apheresis have established specialist clinical pathways, but outcomes are context-specific. Immune adsorption efficacy varies by diagnosis. For NucleoCore, the current marketing page documents molecular targeting and possible pathophysiologic settings; that does not itself demonstrate clinical effectiveness or routine indication. [1–9]
Choosing between POCARD plasma sorbents
| Question | ImmunoCore | Immuno-Adsopak | ABO Adsopak | Lipopak | NucleoCore |
|---|---|---|---|---|---|
| Primary target | Ig / immune complexes | Ig / immune complexes | Anti-A and/or anti-B | LDL / Lp(a) | cfDNA / DNA structures |
| Clinical pathway | Selected Ig immunoadsorption | Multi-cycle / series of Ig IA | ABO-incompatible transplantation | Lipid apheresis | Specialist/investigational |
| Column use | Single-use | Patient-specific reuse | Size-dependent | Patient-specific regeneration | Single-use |
| Monitoring focus | Autoantibody / Ig | Autoantibody / Ig | Anti-A/B titers | LDL-C and Lp(a) | Protocol-defined cfDNA assays |
| Special caution | Ig loss, replacement therapy timing | Regeneration traceability | Correct A/B target and titration | Chronic ASCVD/lipid goals | Outcome evidence and protocol approval |
This table compares therapeutic logic, not effectiveness; products are not clinically interchangeable. Target-removal performance and safety depend on the protocol, patient, machine, column variant and local IFU.
POCARD separated-plasma adsorption prescription worksheet
Safety and completion checklist
For specialist team documentation only. No numerical settings should be signed without the current manufacturer IFU and patient-specific clinical authorization.
Prescription Worksheet — Complete & Print
Fill in this patient-specific prescription worksheet on screen, copy the completed fields, or print the worksheet alone. Blank fields are intentional; the worksheet does not determine appropriate device settings or constitute an authorized medical order.
Mandatory clinical verification: the signed institutional order, current model-specific manufacturer IFU, applicable regulatory authorization and patient-specific medical review take precedence. The worksheet remains entirely local to this page; its entries are not saved or transmitted.
Primary links and interpretation of product claims
- POCARD International — current product catalogue (2026). Source for catalogued product families and plasma-vs-blood route assessment.
- POCARD — ImmunoCore. Single-use plasma immunoadsorption, 300 mL housing and manufacturer-listed disease contexts.
- POCARD — Immuno-Adsopak. Regenerable plasma Ig adsorber; current webpage mentions five uses. Reuse details require full IFU.
- POCARD — ABO Adsopak. Anti-A, anti-B and anti-A/anti-B product family; manufacturer-labeled plasma route.
- POCARD — Lipopak. LDL/Lp(a) plasma apheresis; 300 mL housing; manufacturer states 18 cycles.
- POCARD — NucleoCore. 50 and 150 mL single-use plasma sorption columns for cfDNA and DNA-containing structures; note the webpage contains differing descriptions of the adsorbent matrix.
- POCARD — Immunoadsorption product review (February 2026; PDF). Manufacturer educational brochure on ImmunoCore/Immuno-Adsopak and the technical concept of plasma immunoadsorption.
- POCARD — Immunoadsorption for transplantation (February 2026; PDF). Model-specific brochure data, example ≤60 mL/min ImmunoCore plasma flow, ABO A/B/AB model variants, and illustrative transplant protocols. A brochure is not a full IFU.
- Pokrovsky et al. — Therapeutic apheresis for lipoprotein(a) management (Current Atherosclerosis Reports, 2020; PDF). Context for specialist lipoprotein apheresis; not Lipopak product operating instructions.
- POCARD — Adsorption column structure and plasma sorption principles. Conceptual technique and extracorporeal safety requirements; not model-specific priming or pressure settings.