1. Definition and clinical purpose
Glycosorb® ABO is an antigen-specific, single-use immunoadsorption column designed to remove circulating anti-A and/or anti-B isohemagglutinins from separated patient plasma. It is not synonymous with all immunoadsorption technologies or with conventional therapeutic plasma exchange (TPE).
Separated plasma passes through the ABO antigen-bearing adsorbent and is returned to the patient. Unlike TPE, routine exchange of the treated plasma for albumin or donor plasma is generally not needed.
2. Device selection and circuit
| Column | General selection principle |
|---|---|
| Glycosorb® A | Targets anti-A antibodies when indicated by donor–recipient ABO mismatch. |
| Glycosorb® B | Targets anti-B antibodies when indicated. |
| Glycosorb® A/B | Targets both anti-A and anti-B for selected mismatches; confirm exact product configuration. |
The treatment typically includes vascular access, anticoagulation, plasma separation (centrifugal or membrane), a single-use ABO-specific column, and plasma reinfusion. Confirm device compatibility, tubing, priming, allowable pressures and flow with the current instructions for use (IFU).
3. Indications and multidisciplinary eligibility
- ABO-incompatible kidney transplantation: selective removal of anti-A/B isohemagglutinins before surgery as part of a coordinated desensitization regimen.
- After transplantation: additional procedures may be considered when antibody rebound is accompanied by relevant clinical or graft findings, according to the transplant service protocol.
- Other uses: selected transplant and hematologic applications appear in limited reports and should not be treated as routine indications.
Assess ABO phenotype (including clinically relevant subgroups), HLA sensitization and donor-specific antibodies, immunosuppressive plan, infectious and bleeding risks, vascular access, and assay capabilities before initiating treatment.
For ABO-incompatible kidney transplantation, French 2024 guidance emphasizes available round-the-clock apheresis and anti-CD20 care, and the measurement of both IgG and IgM isohemagglutinins.
4. Antibody titers and treatment targets
Measure recipient anti-A and/or anti-B IgG and IgM titers before desensitization, before and after treatments as clinically indicated, and around the transplant period. Use one standardized laboratory method for serial results: titers are assay-dependent and are not numerically interchangeable between laboratories.
| Decision point | Practical approach |
|---|---|
| Baseline | Establish relevant IgG and IgM titers, ABO mismatch and risk factors. |
| Preoperative target | Defined by transplant program. Published thresholds vary (e.g., ≤1:4 or ≤1:8 in selected protocols; other contemporary centers use different cutoffs). |
| Response to each session | Compare standardized pre/post titers with the intended target and trajectory. |
| Postoperative rebound | Interpret alongside graft function, clinical findings and rejection assessment; an isolated titer increase is not automatically an indication for treatment. |
5. Prescription and device parameters
| Parameter | What to prescribe / document |
|---|---|
| Adsorber model | Glycosorb A, B, or A/B; manufacturer, lot and expiry. |
| Device and separator | System, circuit, compatible column, plasma separation mode and access. |
| Plasma volume processed | Individualized to titers, clinical response, estimated plasma volume and IFU. |
| Plasma flow / blood flow | Set using separator and column specifications; not a universal number. |
| Anticoagulation | Specify validated citrate/heparin protocol and monitoring. |
| Replacement fluid | Usually no routine plasma replacement because adsorbed plasma is returned; prescribe fluids only as clinically indicated. |
| Session duration | Variable, depending on plasma flow and volume processed. |
| Schedule | Specify planned treatment dates and antibody-based reassessment. |
Published practice is heterogeneous: a 2026 German multicenter survey found a median of 3 plasma volumes processed per session for standard ABO-specific IA (interquartile range 2.5–3; observed range 1–5). One North American series described 2.5 plasma volumes per session. Other studies treated much larger absolute volumes under specific protocols. These are observations, not universal device settings.
6. Estimated plasma volume and planning calculator
An estimate of patient plasma volume can aid planning and documentation. The result below is not a prescription and does not establish the number of liters that the Glycosorb column can safely process.
Calculation illustrates published treatment-volume multiples only. Final volume requires a clinician order and device validation.
Distinction: plasma processed through the adsorber is largely returned, unlike plasma removed and replaced in conventional TPE.
7. Scheduling and accompanying treatment
Plan treatment around the transplant date and the evolution of measured isohemagglutinins. Manufacturer information notes that some programs perform approximately 1–3 sessions before transplant, while published multi-session protocols may require more. Some retrospective series scheduled sessions on multiple days between day −7 and day −1.
Desensitization is usually combined with a transplant-specific immunosuppressive protocol. B-cell depletion, maintenance immunosuppression, induction therapy and infection prophylaxis are managed by the transplant team; this guide intentionally provides no universal drug dosing regimen.
8. Anticoagulation, access, and safety
- Anticoagulation: citrate or heparin according to separator, circuit, patient bleeding risk and institutional protocol; follow device labeling.
- Vascular access: peripheral or central venous access as feasible and compatible with required blood flow.
- Hemodynamics: monitor hypotension, allergic symptoms, circuit integrity, clotting, and fluid balance.
- Citrate monitoring: assess symptoms and ionized calcium as relevant; give calcium according to a validated protocol.
- Medication review: assess ACE inhibitors and other drugs against adsorber/circuit instructions and local policy.
- Bleeding and infection: assess vascular access, anticoagulation, immune suppression and surgical timing.
Device-specific contraindications, tubing compatibility, pressure alarms, priming solutions and maximum permitted flows must be read from the current IFU before treatment.
9. Clinical and laboratory monitoring
| Time | Monitoring |
|---|---|
| Before course | ABO mismatch, anti-A/B IgG and IgM titers, CBC, platelet count, coagulation and fibrinogen as appropriate, renal function, infection status, access and consent. |
| Before each session | Relevant titers, hemodynamics, calcium/electrolytes if indicated, vascular access and device checks. |
| During session | Blood/plasma flow, pressures, anticoagulation tolerance, symptoms, ionized calcium when appropriate, volume processed and alarms. |
| After session | Anti-A/B titers by the same assay, tolerance, adverse events and plans for subsequent sessions. |
| Post-transplant | Graft function and rejection surveillance; antibody titer schedule per transplant protocol (some cohorts monitored daily in week 1 and every 2 days in week 2). |
10. Standardized Glycosorb prescription template
Use this checklist for clinical documentation. It is not a validated medical order or a substitute for manufacturer operating instructions.
| Field | Complete before treatment |
|---|---|
| Indication and transplant date | Diagnosis, donor/recipient ABO and planned procedure date |
| Baseline / target titers | Anti-A/B IgG and IgM; measurement methodology |
| Adsorber | Glycosorb A, B or A/B; lot, expiry, single-use verification |
| EPV and plasma processed | Patient weight, hematocrit, calculated EPV, ordered target volume |
| System and access | Plasma separator, circuit and access type |
| Flows and anticoagulation | Device-validated settings and clinical protocol |
| Monitoring | Vitals, titers, calcium and additional laboratory tests |
| Schedule and stopping rules | Dates, response thresholds, complications and escalation plan |
| Clinical authorization | Prescribing physician and transplant/apheresis service |
Prescription Worksheet — Complete & Print
Fill in this patient-specific prescription worksheet on screen, copy the completed fields, or print the worksheet alone. Blank fields are intentional; the worksheet does not determine appropriate device settings or constitute an authorized medical order.
Mandatory clinical verification: the signed institutional order, current model-specific manufacturer IFU, applicable regulatory authorization and patient-specific medical review take precedence. The worksheet remains entirely local to this page; its entries are not saved or transmitted.
12. References and source hierarchy
- Glycorex Transplantation AB. Glycosorb® ABO — Product information. Manufacturer overview (not a replacement for the device-specific IFU).
- Agence de la biomédecine (2024). French clinical practice guidelines for living kidney donation, section on ABO-incompatible transplantation.
- ISOT (2026). Position statement on immunological evaluation in kidney transplantation.
- Reuter et al. (2026). ABO-incompatible kidney transplantation with high isoagglutinin titres: German multicentre survey.
- North American Glycosorb cohort (2020). The first North American experience using Glycosorb immunoadsorption columns.
- Indian prospective cohort (2020). Use of immunoadsorption columns in ABO-incompatible renal transplantation.
- European Association of Urology. Renal transplantation guidelines.
- ASFA (2023). Guidelines on the use of therapeutic apheresis in clinical practice.