Therapeutic Apheresis · Clinical Practice Guide

Glycosorb® ABO

Antigen-Specific Immunoadsorption — Practical Prescription Guide
ABO-incompatible transplantation · Single-use anti-A / anti-B adsorption

1. Definition and clinical purpose

Glycosorb® ABO is an antigen-specific, single-use immunoadsorption column designed to remove circulating anti-A and/or anti-B isohemagglutinins from separated patient plasma. It is not synonymous with all immunoadsorption technologies or with conventional therapeutic plasma exchange (TPE).

Primary clinical use: desensitization for ABO-incompatible organ transplantation, particularly kidney transplantation, within a multidisciplinary transplant program. Published work also describes selected post-transplant and hematopoietic stem-cell transplant applications; use outside established indications requires specialist assessment.

Separated plasma passes through the ABO antigen-bearing adsorbent and is returned to the patient. Unlike TPE, routine exchange of the treated plasma for albumin or donor plasma is generally not needed.

2. Device selection and circuit

ColumnGeneral selection principle
Glycosorb® ATargets anti-A antibodies when indicated by donor–recipient ABO mismatch.
Glycosorb® BTargets anti-B antibodies when indicated.
Glycosorb® A/BTargets both anti-A and anti-B for selected mismatches; confirm exact product configuration.

The treatment typically includes vascular access, anticoagulation, plasma separation (centrifugal or membrane), a single-use ABO-specific column, and plasma reinfusion. Confirm device compatibility, tubing, priming, allowable pressures and flow with the current instructions for use (IFU).

Single use: manufacturer product information describes a new column for each treatment. Reports investigating column reuse do not supersede labeling; do not use them as authorization to reuse a device.

3. Indications and multidisciplinary eligibility

  • ABO-incompatible kidney transplantation: selective removal of anti-A/B isohemagglutinins before surgery as part of a coordinated desensitization regimen.
  • After transplantation: additional procedures may be considered when antibody rebound is accompanied by relevant clinical or graft findings, according to the transplant service protocol.
  • Other uses: selected transplant and hematologic applications appear in limited reports and should not be treated as routine indications.

Assess ABO phenotype (including clinically relevant subgroups), HLA sensitization and donor-specific antibodies, immunosuppressive plan, infectious and bleeding risks, vascular access, and assay capabilities before initiating treatment.

For ABO-incompatible kidney transplantation, French 2024 guidance emphasizes available round-the-clock apheresis and anti-CD20 care, and the measurement of both IgG and IgM isohemagglutinins.

4. Antibody titers and treatment targets

Measure recipient anti-A and/or anti-B IgG and IgM titers before desensitization, before and after treatments as clinically indicated, and around the transplant period. Use one standardized laboratory method for serial results: titers are assay-dependent and are not numerically interchangeable between laboratories.

Decision pointPractical approach
BaselineEstablish relevant IgG and IgM titers, ABO mismatch and risk factors.
Preoperative targetDefined by transplant program. Published thresholds vary (e.g., ≤1:4 or ≤1:8 in selected protocols; other contemporary centers use different cutoffs).
Response to each sessionCompare standardized pre/post titers with the intended target and trajectory.
Postoperative reboundInterpret alongside graft function, clinical findings and rejection assessment; an isolated titer increase is not automatically an indication for treatment.
No universal titer threshold: a 2026 practice statement suggests center-specific pretransplant targets often between ≤1:8 and ≤1:32. Do not substitute a literature threshold for your transplant program’s protocol.

5. Prescription and device parameters

ParameterWhat to prescribe / document
Adsorber modelGlycosorb A, B, or A/B; manufacturer, lot and expiry.
Device and separatorSystem, circuit, compatible column, plasma separation mode and access.
Plasma volume processedIndividualized to titers, clinical response, estimated plasma volume and IFU.
Plasma flow / blood flowSet using separator and column specifications; not a universal number.
AnticoagulationSpecify validated citrate/heparin protocol and monitoring.
Replacement fluidUsually no routine plasma replacement because adsorbed plasma is returned; prescribe fluids only as clinically indicated.
Session durationVariable, depending on plasma flow and volume processed.
ScheduleSpecify planned treatment dates and antibody-based reassessment.

Published practice is heterogeneous: a 2026 German multicenter survey found a median of 3 plasma volumes processed per session for standard ABO-specific IA (interquartile range 2.5–3; observed range 1–5). One North American series described 2.5 plasma volumes per session. Other studies treated much larger absolute volumes under specific protocols. These are observations, not universal device settings.

6. Estimated plasma volume and planning calculator

An estimate of patient plasma volume can aid planning and documentation. The result below is not a prescription and does not establish the number of liters that the Glycosorb column can safely process.

Estimated plasma volume (L) = 0.065 × body weight (kg) × (1 − hematocrit fraction)
Estimated plasma volume—
Illustrative plasma volume processed—

Calculation illustrates published treatment-volume multiples only. Final volume requires a clinician order and device validation.

Distinction: plasma processed through the adsorber is largely returned, unlike plasma removed and replaced in conventional TPE.

7. Scheduling and accompanying treatment

Plan treatment around the transplant date and the evolution of measured isohemagglutinins. Manufacturer information notes that some programs perform approximately 1–3 sessions before transplant, while published multi-session protocols may require more. Some retrospective series scheduled sessions on multiple days between day −7 and day −1.

Desensitization is usually combined with a transplant-specific immunosuppressive protocol. B-cell depletion, maintenance immunosuppression, induction therapy and infection prophylaxis are managed by the transplant team; this guide intentionally provides no universal drug dosing regimen.

Further IA is guided by measured antibodies, surgical timing, patient status and local transplant criteria, not solely by a fixed session count.

8. Anticoagulation, access, and safety

  • Anticoagulation: citrate or heparin according to separator, circuit, patient bleeding risk and institutional protocol; follow device labeling.
  • Vascular access: peripheral or central venous access as feasible and compatible with required blood flow.
  • Hemodynamics: monitor hypotension, allergic symptoms, circuit integrity, clotting, and fluid balance.
  • Citrate monitoring: assess symptoms and ionized calcium as relevant; give calcium according to a validated protocol.
  • Medication review: assess ACE inhibitors and other drugs against adsorber/circuit instructions and local policy.
  • Bleeding and infection: assess vascular access, anticoagulation, immune suppression and surgical timing.

Device-specific contraindications, tubing compatibility, pressure alarms, priming solutions and maximum permitted flows must be read from the current IFU before treatment.

9. Clinical and laboratory monitoring

TimeMonitoring
Before courseABO mismatch, anti-A/B IgG and IgM titers, CBC, platelet count, coagulation and fibrinogen as appropriate, renal function, infection status, access and consent.
Before each sessionRelevant titers, hemodynamics, calcium/electrolytes if indicated, vascular access and device checks.
During sessionBlood/plasma flow, pressures, anticoagulation tolerance, symptoms, ionized calcium when appropriate, volume processed and alarms.
After sessionAnti-A/B titers by the same assay, tolerance, adverse events and plans for subsequent sessions.
Post-transplantGraft function and rejection surveillance; antibody titer schedule per transplant protocol (some cohorts monitored daily in week 1 and every 2 days in week 2).

10. Standardized Glycosorb prescription template

Use this checklist for clinical documentation. It is not a validated medical order or a substitute for manufacturer operating instructions.

FieldComplete before treatment
Indication and transplant dateDiagnosis, donor/recipient ABO and planned procedure date
Baseline / target titersAnti-A/B IgG and IgM; measurement methodology
AdsorberGlycosorb A, B or A/B; lot, expiry, single-use verification
EPV and plasma processedPatient weight, hematocrit, calculated EPV, ordered target volume
System and accessPlasma separator, circuit and access type
Flows and anticoagulationDevice-validated settings and clinical protocol
MonitoringVitals, titers, calcium and additional laboratory tests
Schedule and stopping rulesDates, response thresholds, complications and escalation plan
Clinical authorizationPrescribing physician and transplant/apheresis service

Prescription Worksheet — Complete & Print

Fill in this patient-specific prescription worksheet on screen, copy the completed fields, or print the worksheet alone. Blank fields are intentional; the worksheet does not determine appropriate device settings or constitute an authorized medical order.

Prescription fieldClinician entry / verification
Patient & clinical indication
Patient identifier / hospital record
Treatment date / time
Clinical service / prescribing physician
Diagnosis / indication
Therapeutic objective / response criteria
Device & patient assessment
Exact product / modality
Product lot / IFU revision / local authorization
Device platform, separator and extracorporeal circuit
Vascular access
Weight / hematocrit / estimated plasma volume
Treatment prescription
Blood flow and plasma flow
Processed plasma target / treatment volume
Planned duration and treatment frequency
Procedure-specific details
Donor and recipient ABO groups
Anti-donor IgG / IgM: baseline and target
Transplant / intervention schedule
Column antigen and single-use verification
Safety, monitoring & authorization
Priming, fluid return and balance
Anticoagulant regimen and monitoring
Medication review / contraindications
Baseline and procedural monitoring
Stopping / escalation criteria
Consent / physician validation / signature

Mandatory clinical verification: the signed institutional order, current model-specific manufacturer IFU, applicable regulatory authorization and patient-specific medical review take precedence. The worksheet remains entirely local to this page; its entries are not saved or transmitted.

12. References and source hierarchy

  1. Glycorex Transplantation AB. Glycosorb® ABO — Product information. Manufacturer overview (not a replacement for the device-specific IFU).
  2. Agence de la biomédecine (2024). French clinical practice guidelines for living kidney donation, section on ABO-incompatible transplantation.
  3. ISOT (2026). Position statement on immunological evaluation in kidney transplantation.
  4. Reuter et al. (2026). ABO-incompatible kidney transplantation with high isoagglutinin titres: German multicentre survey.
  5. North American Glycosorb cohort (2020). The first North American experience using Glycosorb immunoadsorption columns.
  6. Indian prospective cohort (2020). Use of immunoadsorption columns in ABO-incompatible renal transplantation.
  7. European Association of Urology. Renal transplantation guidelines.
  8. ASFA (2023). Guidelines on the use of therapeutic apheresis in clinical practice.
Evidence hierarchy: current IFU and institutional SOP govern operation; transplant guidelines govern indication and eligibility; published cohorts illustrate feasible approaches but do not set universally applicable device parameters.