Which Fresenius adsorbers are covered?
Plasma adsorption means first separating plasma from the cellular blood components, passing that separated plasma through a sorbent column, and returning the processed plasma together with the cells. Unlike therapeutic plasma exchange (TPE), the processed plasma is generally returned rather than discarded and replaced.
Exclusions: DALI 500/750/1000/1250 (direct whole-blood lipoprotein adsorption), MONET (plasma fractionation by filtration, not a sorbent), plasma separators and machines. Historical IMMUNOSORBA protein-A columns lack sufficiently clear evidence of current catalogue-based commercial availability to include here. PROMETH 01/02 (Prometheus liver support) are excluded from the active prescriber models: the Prometheus system was withdrawn in Germany in 2021, although publications report use in some Asian countries. Confirm country-specific purchasing status separately before any local prescription. [1,8,11]
Market-listed models and adsorption targets
GLOBAFFIN
IgG-focused Twin-column
Ligand: synthetic peptide GAM146 on agarose/Sepharose. Particularly binds IgG1, IgG2 and IgG4; also immune complexes, with lower affinity for IgG3, IgM and IgA.
Usage: two columns alternately adsorb and regenerate. Same-patient reuse is allowed only by the current IFU and approved reprocessing system.
Fresenius current product page and Rev 06.2 IFU. [2,5]LIGASORB®
Protein A Single-use per session
Ligand: recombinant staphylococcal protein A on polymethacrylate beads, with strong immunoglobulin-binding capacity.
Usage: a single-use, multiple-pass column that undergoes intra-session adsorption/regeneration cycles. No reuse for another session should be inferred from regeneration during a session.
Current product catalogue; peer-reviewed technical study. [1,6]IgEnio®
IgE-selective Single-pass
Ligand: recombinant anti-IgE single-chain variable fragment (scFv).
Usage: single-use, single-pass adsorption of IgE in separated plasma. Published research focuses on severe allergic disease; indication and eligibility must be checked against the current local IFU.
Current product catalogue; published clinical investigations. [1,7,9]| Product | Target | Plasma flow path | Reuse rule | 2026 commercial evidence |
|---|---|---|---|---|
| GLOBAFFIN | IgG / autoantibodies; immune complexes | Separated plasma, paired alternating columns + dedicated adsorption controller | Regenerable during session; same-patient reuse per IFU only | Active Fresenius catalogue, product page, IFU [1,2,5] |
| LIGASORB | Immunoglobulins / pathogenic antibodies via protein A | Separated plasma, single column with repeated adsorption–elution cycles | One session only; regenerable during that session | Active Fresenius catalogue [1,6] |
| IgEnio | IgE | Separated plasma, single-use single-pass column | No regeneration or between-session reuse | Active Fresenius catalogue [1,7,9] |
Catalogue-listed is not equivalent to in-stock or locally reimbursable. Fresenius' current platform page explicitly supports GLOBAFFIN with ADAsorb; do not assume the same current machine compatibility for LIGASORB or IgEnio without written confirmation. [3]
Clinical indications and intended endpoints
Intended for selected conditions where pathogenic IgG contributes to disease and conventional therapies are insufficient. Manufacturer IFU examples include autoimmune disease, pretransplant desensitization and acute antibody-mediated rejection; the strength of evidence varies substantially by diagnosis.
Endpoints: disease-specific clinical response, antibody trend when interpretable, organ function, tolerance and need for adjunctive therapy. [5]
Investigated in antibody-mediated autoimmune diseases, including published neurologic and autoimmune blistering-disease cohorts. Its single-session format offers a different operational pattern from the GLOBAFFIN twin columns.
Endpoints: clinically meaningful symptom/organ improvement and appropriate immunoglobulin or autoantibody monitoring. [6,10]
Published pilot clinical settings include severe allergic asthma and atopic dermatitis. The literature contains study-specific schedules and responses; they do not establish a universal routine indication or a first-line alternative to guideline-directed allergy treatment.
Endpoints: total/specific IgE as applicable, validated disease scores, exacerbations, steroid need and adverse events. [7,9]
Specify the diagnosis, conventional treatments tried, approved/local indication, anticipated benefit, contraindications, alternative options, consent and predefined stopping criteria before starting any plasma adsorption session.
Evaluate disease-specific professional guidance; do not treat all autoimmune diseases as equivalent indications.
Conceptual circuit configuration
While column A is loaded with separated plasma, column B can be regenerated, then the roles alternate through an adsorption controller. The clinical plasma stream is separated from regenerant and waste streams. Confirm valve sequences and rinsing using the actual ADAsorb setup and disposable IFUs. [3,5]
LIGASORB is one column with repeated intra-session adsorption/elution cycles (not between-session reuse). IgEnio is single-use and single-pass. Each requires its own approved separator, tubing and monitoring interface, not an improvised interchangeable cartridge connection. [6,7]
The above is only a process concept: pressure-monitoring sites, air detectors, volume sensors, isolation valves, plasma disposal during regeneration and all emergency bypass paths must follow the exact approved equipment manuals.
Model-specific prescribing inputs
| Variable | Document in order | Evidence / restriction |
|---|---|---|
| Indication and measurable goal | Disease, target autoantibody or IgE, clinical endpoint and reassessment plan | IFU and disease guidance take priority over a device's marketing description. |
| Column identity | GLOBAFFIN / LIGASORB / IgEnio, product code, batch, expiry, IFU revision | No interchangeability; confirm local sale and indications. |
| Primary blood flow (Qb) | Patient-specific mL/min, separator type, hematocrit, access performance | No generalized flow rate across models; use approved separator and column operating limits. |
| Secondary plasma flow (Qp) | Prescribed mL/min and acceptable range; column pressures / cycle constraints | Different machinery and media mean different limits; do not transfer published protocol values. |
| Processed plasma volume | Target L, multiple of estimated plasma volume (EPV), planned duration | GLOBAFFIN: manufacturer IFU generally describes 1.5–2.5 × patient plasma volume per session; greater volumes have limited experience. LIGASORB/IgEnio: use model IFU and protocol, not that GLOBAFFIN range. [5] |
| Session pattern | Number of sessions, spacing, treatment response and stop threshold | Not universal. Literature schedules are indication- and study-specific. [6,7,9] |
| Regeneration / single-use rule | Required column count, adsorption cycles and patient-specific labeling | GLOBAFFIN twin system with IFU-regulated same-patient reuse; LIGASORB one session with internal regeneration; IgEnio single pass. |
| Anticoagulation and fluids | Agent, dose, monitoring, calcium/volume plan, regeneration waste balance | Use approved machine protocols and individual bleeding/citrate risk; avoid generic anticoagulant dosing. |
Processed plasma and estimated plasma-volume ratio
Enter clinician-selected parameters; there are deliberately no default treatment settings. The estimator calculates plasma passing through a column, not plasma removed or exchanged. It cannot determine safe device settings or a therapeutic dose.
Approximate EPV (L) = 0.065 × weight (kg) × (1 − hematocrit/100). This simplified estimate is not a validated individual plasma-volume measurement. For a regenerating system, total clock time is not necessarily active plasma-flow time.
Enter your clinical values to calculate.
Pre-treatment setup and clinical checks
- Check the precise product, approved indication, expiry, seal integrity, mandatory single-use labeling, patient identification and manufacturer-approved disposables.
- Verify plasma separator and adsorption monitor compatibility, pressure/air/leak alarms, approved priming solutions and software/cycle settings.
- With GLOBAFFIN, confirm the correct paired columns, exclusive patient allocation, the device's dedicated flushing procedure and any approved same-patient storage/reuse requirements. The official IFU states that delivery or storage solutions must be removed before clinical plasma perfusion. [5]
- With LIGASORB, distinguish intra-session regeneration from physical reuse in a subsequent treatment; confirm the one-column single-session instructions.
- With IgEnio, confirm single-use single-pass setup and approved separator route; do not insert a regeneration loop.
- Review allergy history, recent infusion therapies, central/peripheral access suitability, net extracorporeal volume and anticipated fluid shifts.
Anticoagulation and fluid-balance safety
Specify anticoagulation according to the approved plasma separator, adsorber and patient profile. Citrate-based anticoagulation may contribute to ionized calcium reduction; hepatic impairment, shock or impaired citrate metabolism require individual assessment. Heparin carries bleeding and HIT-related risks. A drug, ratio or dose from a paper must not be copied across devices.
Its IFU discusses anticoagulation, calcium and volume monitoring, and the fluid load from frequent regeneration/rinsing cycles. Avoid treating a regenerative adsorption circuit as equivalent to routine TPE. [5]
Use device-specific supported anticoagulation. Published citrate/heparin regimens are context only until locally checked; do not extrapolate GLOBAFFIN regeneration-fluid or anticoagulation instructions. [6,7]
Record input and output including citrate, saline, regeneration solutions, return fluids, plasma lost to waste, and clinical fluid status. Monitor for hypocalcemia when citrate is used.
Baseline, intraprocedural and post-session assessment
| Time | Required clinical/laboratory review | Product-specific emphasis |
|---|---|---|
| Before | Vitals, access, medication/allergy/ACE inhibitor review; CBC/platelets, coagulation/fibrinogen if indicated, electrolytes and calcium; disease-specific target biomarkers | GLOBAFFIN IFU identifies low fibrinogen and perioperative bleeding issues, as well as bradykinin-related medication warnings. [5] |
| During | BP, pulse, symptoms, blood/plasma flow, adsorber/line pressures, extracorporeal volume, air/clotting alarms; anticoagulation and calcium as appropriate | Watch for serious reaction, hypotension, protein/antibody loss and regeneration-fluid imbalances. |
| Immediately after | Clinical tolerance, fluid balance, access check, CBC/coagulation/electrolytes as indicated, target antibody or IgE levels when clinically meaningful | Interpret lab reductions alongside procedure-specific clinical outcomes. |
| Between sessions | Symptoms and organ function, infection and bleeding risk, biomarker rebound, response to disease-specific therapy | Decide continue/reassess/stop using predefined clinical criteria and local protocol. |
Contraindications, complications and stop rules
- Unstable circulation or inability to tolerate an extracorporeal circuit
- Hypersensitivity to the specific materials/ligands or relevant prior severe reaction
- Bleeding or unsafe coagulation profile; GLOBAFFIN IFU also identifies fibrinogen thresholds requiring particular attention [5]
- Inadequate access, inability to anticoagulate safely or lack of compatible certified equipment
- Acute systemic infection and severe cardiac/organ dysfunction requiring individualized risk–benefit review
- Medication interaction and significant antibody/protein depletion
- Severe hypotension, dyspnea, bronchospasm, syncope or suspected anaphylactoid reaction
- Uncontrolled bleeding, major calcium disturbance, arrhythmia or deteriorating consciousness
- Persistent air/leak/pressure alarm, suspected column compromise, clotting or unexpected hemolysis
- Unacceptable cumulative immunoglobulin depletion, serious infection, or no longer favorable benefit–risk
- Unexpected incompatibility of the actual cartridge, machine or cycle protocol
Which column matches which target?
| Decision item | GLOBAFFIN | LIGASORB | IgEnio |
|---|---|---|---|
| Primary target | IgG autoantibodies, immune complexes | IgG/immunoglobulins via protein A | IgE |
| Ligand | Synthetic peptide GAM146 | Recombinant protein A | IgE-specific scFv |
| Adsorber configuration | Two alternating regenerable columns | Single column, multiple adsorption passes and intra-session regeneration | Single-use, single-pass |
| Between-session reuse | Permitted only for same patient within approved IFU/reprocessing rules | No, single-use treatment | No |
| Public current compatibility information | ADAsorb currently specifically supported in Fresenius platform listing [3] | Confirm currently supplied controller and consumables with manufacturer | Confirm current separator/connection kit in local IFU |
| Common clinical research setting | Autoantibody-mediated disorders / transplantation | Autoimmune disorders | Severe allergic disease / IgE depletion |
No ranking is implied. Clinical justification, authorized indications, local supply and documented equipment compatibility determine the appropriate treatment pathway.
Printable prescription checklist
Documentation aid only. Incomplete fields must be resolved from the current model-specific IFU and clinician prescription before treatment.
Prescription Worksheet — Complete & Print
Fill in this patient-specific prescription worksheet on screen, copy the completed fields, or print the worksheet alone. Blank fields are intentional; the worksheet does not determine appropriate device settings or constitute an authorized medical order.
Mandatory clinical verification: the signed institutional order, current model-specific manufacturer IFU, applicable regulatory authorization and patient-specific medical review take precedence. The worksheet remains entirely local to this page; its entries are not saved or transmitted.
Current catalogue, instructions and published evidence
- Fresenius Medical Care — Professional Products (current catalogue). Lists GLOBAFFIN, LIGASORB and IgEnio as adsorbers; global market availability disclaimer.
- Fresenius Medical Care — GLOBAFFIN product detail. GAM peptide chemistry, IgG affinity, use with two alternating columns and same-patient reuse.
- Fresenius Medical Care — Therapeutic apheresis platforms. GLOBAFFIN/ADAsorb compatibility; identifies older Art Universal platform as no longer manufactured.
- Fresenius Medical Care — Immunoadsorption overview. Mechanism, plasma-stream treatment and GLOBAFFIN indications.
- Fresenius Medical Care — GLOBAFFIN Instructions for Use (35840034, rev. 06.2). Product-specific restrictions, 1.5–2.5 patient EPV example, regeneration, same-patient use, ACE/ARNI and fibrinogen warnings. Always check whether a newer local revision supersedes this public version.
- Schossee et al. (2022), Vox Sanguinis — single-use multiple-pass protein A adsorber LIGASORB. Technical clinical report of intra-session regenerability and plasma-route use.
- Extracorporeal IgE immunoadsorption in allergic asthma (2017). Describes IgEnio scFv ligand and a randomized pilot study.
- Fresenius Medical Care — Lipoprotein apheresis. Explicitly distinguishes whole-blood DALI adsorption from plasma MONET filtration.
- Meyersburg et al. (2020), Journal of Clinical Apheresis — IgEnio in atopic dermatitis. Clinical research context and study-specific schedules.
- Holtsche et al. (2026), JDDG — LIGASORB in bullous pemphigoid. Published experience with a single-use regenerable protein-A column.
- Friebus-Kardash et al. (2025), Artificial Organs — Prometheus market withdrawal in Germany. Reports withdrawal in Germany in 2021 and continued use in some Asian countries; not proof of 2026 French commercial availability.