1. Scope and product selection
This guide covers only Biosky DX-series disposable bilirubin adsorption columns used with separated plasma, as described by Foshan Biosun Medical Technology and associated Biosky / Baihe documentation. It does not cover cartridges intended exclusively for extracorporeal whole-blood perfusion.
| Included device | Plasma-circuit role | Verification required |
|---|---|---|
| Biosky DX series | Bilirubin and bile-acid adsorption from separated plasma using an anion-exchange resin. | Exact model, local registration, current manufacturer instructions for use (IFU), compatible separator and pump. |
Historical product literature lists DX150, DX250 and DX350 sizes. Model availability, cartridge capacity and use authorization must be confirmed for the treatment country and the exact supplied product. A product catalogue is not a substitute for its current IFU. Historical technical brochure.
2. Treatment principle and adsorption targets
After blood is separated, the plasma flows through the DX column, where an anion-exchange resin binds bilirubin through charge-related interactions. Manufacturer and related product literature also describes bile-acid adsorption. Cellular blood components do not traverse the plasma adsorber.
- Primary biochemical target: circulating bilirubin (conjugated and other relevant fractions, depending on adsorption characteristics).
- Additional target: bile acids, as reported in the series literature.
- Role: adjunctive extracorporeal plasma purification in selected severe hyperbilirubinemia / cholestatic liver disorders.
- Limitation: bilirubin reduction is a biochemical endpoint; it does not prove recovery of hepatic synthetic function or improved survival.
3. Indications and patient selection
| Clinical context | Reason to consider DX plasma adsorption | Clinical qualification |
|---|---|---|
| Severe hyperbilirubinemia / cholestasis | Selective reduction of circulating bilirubin and potentially bile acids. | Consider only after identifying and treating the cause; assess the severity of symptoms, risks and alternatives. |
| Acute or acute-on-chronic liver dysfunction | Potential adjunctive bilirubin removal in selected patients. | Evidence of survival benefit for this specific column is not established; follow hepatology / transplant-team recommendations. |
| Selected liver diseases described by manufacturer | Supportive management where bilirubin removal is a defined objective. | Manufacturer descriptions are not independent guideline endorsements or proof of outcome benefit. |
Before prescribing: document the clinical objective, disease severity, expected response, available alternatives (including TPE when indicated), relevant contraindications/precautions, and planned reassessment.
4. Prescription parameters — device-specific checklist
No reliable universal DX prescription for plasma-flow rate, treatment duration, processed plasma volume or anticoagulant dose can be established from the available public product descriptions. These must be taken from the current IFU of the exact DX model and the compatible plasma separator and platform.
| Item | Prescription requirement |
|---|---|
| Exact adsorber model | Record DX variant, lot, expiry, single-use status, authorization and compatible tubing set. |
| Vascular access / blood flow | Specify appropriate access and permitted flow under the platform and separator IFUs. |
| Plasma flow | Use separator-compatible extraction fraction and the DX model's validated inlet-flow range; do not extrapolate from a different adsorber. |
| Processed plasma volume | Define a patient-specific therapeutic target within column capacity, IFU and local protocol; distinguish plasma processed from plasma removed. |
| Session duration | Calculate from validated flow and processed volume, subject to IFU maximum use time and tolerance. |
| Replacement fluid | Not automatically required solely because plasma passes through an adsorption column; evaluate extracorporeal losses, priming and fluid balance. |
| Anticoagulation | Specify the entire separator–adsorber circuit regimen and monitoring, according to current IFUs and local clinical protocol. |
| Pressure and alarms | Record validated pressure limits and monitoring points before starting. |
| Treatment course | Number and frequency of sessions based on indication, bilirubin trend, clinical response and risk—not a fixed DX-wide schedule. |
5. Educational plasma-volume calculator
An estimated plasma volume (EPV) can help describe a proposed processed plasma volume for an authorized DX procedure. It does not determine a safe device flow, treatment duration or prescribed dose.
Simplified estimate: EPV (L) = 0.065 × weight (kg) × [1 − hematocrit fraction]. Multiples are illustrations only, not established DX doses. A plasma adsorber returns treated plasma; processed plasma volume is not the same as discarded or replacement plasma volume.
6. Priming, circuit setup and anticoagulation
- Identify the correct DX cartridge and compatible plasma separator; verify packaging integrity, expiry and single-use designation.
- Prepare the circuit and perform priming / rinsing exactly as required by the model-specific current IFU. Do not infer priming solution, anticoagulant rinse, or rinse volume from another product.
- Verify the specified plasma inlet/outlet orientation, pressure ports, connections and venous return routing.
- Confirm anticoagulant choice and monitoring against the whole extracorporeal circuit, patient bleeding risk, coagulopathy, and any citrate-related calcium effects.
- Set and document permitted flow ranges, pressure alarms, bypass and emergency stopping procedures before treatment.
7. Clinical and laboratory monitoring
| Stage | Suggested evaluation, individualized to risk |
|---|---|
| Before treatment | Clinical status, hemodynamics, fluid balance, access, CBC/platelets, total/direct bilirubin, liver enzymes, coagulation (PT/INR, fibrinogen as appropriate), electrolytes, calcium, albumin, renal function. |
| During treatment | Vital signs, symptoms, extracorporeal pressure trends, plasma separator function, clotting or leakage, fluid balance, anticoagulation tolerance, access and device alarms. |
| After treatment | Total/direct bilirubin and selected bile acids as appropriate; clinical response; bleeding/access complications and relevant laboratory reassessment. |
| Across sessions | Biomarker trend, underlying disease course, synthetic liver function, adverse events, need for additional or alternative treatment, and continuation criteria. |
Monitoring schedules are not provided as fixed manufacturer-verified intervals in the public DX material. Use the current IFU and local protocol for exact intervals and thresholds.
8. Precautions, adverse events and stopping rules
- Hemodynamic instability or hypotension.
- Bleeding, coagulopathy, thrombocytopenia or fibrinogen depletion, depending on patient and circuit.
- Electrolyte and ionized-calcium disturbances related to the full extracorporeal circuit or anticoagulation.
- Access complications, filter/column clotting, abnormal circuit pressures, disconnection or blood/plasma loss.
- Potential adsorption of concomitant medicines or other plasma components; review dosing around treatment.
The DX manufacturer's public page specifically calls for caution in patients with electrolyte disturbances or coagulation dysfunction. Escalate or stop the procedure according to the physician's order and institutional emergency protocol for severe reactions, ongoing bleeding, unstable vital signs, unresolved alarm conditions or loss of circuit integrity.
9. Efficacy assessment and treatment course
Measure both biochemical response (e.g. changes in bilirubin) and patient-centered outcomes (symptom burden, organ support, clinical deterioration, transplant evaluation). A transient reduction in bilirubin should not be mistaken for meaningful liver recovery.
- Pre/post total and direct bilirubin
- Bile acids where available
- Clinical condition and organ support
- Trend in coagulation and liver function
- Limited response or rapid rebound
- Adverse events or circuit problems
- Better-supported alternative therapy
- Changes in transplant or liver-failure plan
10. Printable DX plasma-adsorption prescription worksheet
Complete and sign within a hospital-approved order set. This blank worksheet does not constitute a standalone prescription.
| Required field | Record / verify |
|---|---|
| Clinical indication and desired endpoint | ________________________________________ |
| DX model / lot / country authorization | ________________________________________ |
| Current IFU revision / local protocol | ________________________________________ |
| Patient weight / hematocrit / EPV | ________________________________________ |
| Access, separator and platform | ________________________________________ |
| Permitted blood and plasma flows | ________________________________________ |
| Planned processed plasma volume | ________________________________________ |
| Session duration / frequency | ________________________________________ |
| Priming and anticoagulation details | ________________________________________ |
| Fluid balance and medication review | ________________________________________ |
| Biological / pressure monitoring | ________________________________________ |
| Clinical stop and response criteria | ________________________________________ |
| Physician / date / authorization | ________________________________________ |
Prescription Worksheet — Complete & Print
Fill in this patient-specific prescription worksheet on screen, copy the completed fields, or print the worksheet alone. Blank fields are intentional; the worksheet does not determine appropriate device settings or constitute an authorized medical order.
Mandatory clinical verification: the signed institutional order, current model-specific manufacturer IFU, applicable regulatory authorization and patient-specific medical review take precedence. The worksheet remains entirely local to this page; its entries are not saved or transmitted.
12. Sources and scientific references
- Foshan Biosun Medical Technology — DX bilirubin adsorption column. Primary manufacturer description: separated-plasma pathway, anion-exchange resin, indications and precautions. Manufacturer product page.
- Biosky / Baihe DX series technical literature. Historical series descriptions, including DX150, DX250 and DX350; model-specific status and current IFUs require verification. Historical brochure (PDF) and Baihe product description.
- Baihe Europe — DX350. Separated-plasma circuit and model information; supplier information is not an independent clinical guideline. Distributor product summary.
- EASL Clinical Practice Guidelines: acute (fulminant) liver failure. Important context for the limits of adsorptive liver-support systems and evidence requirements. EASL guidance.
- Plasma adsorption perfusion versus albumin dialysis for hyperbilirubinemia (2026). Observational outcomes with a different bilirubin adsorber; not device-specific validation of DX. PubMed.