Clinical reference • Extracorporeal blood purification

Hemoadsorption (Whole-Blood)

Practical Prescription Guide — Direct Hemoperfusion & Combined Extracorporeal Circuits

1. Definition and therapeutic objectives

Whole-blood hemoadsorption (HA), also called direct hemoperfusion (HP) when blood traverses a sorbent cartridge, is an extracorporeal technique in which unseparated blood flows through adsorptive media and is returned to the patient. Targets depend on the cartridge's ligand, pore size, surface chemistry and binding capacity. [2]

  • Potential targets: inflammatory mediators, endotoxin, selected endogenous/exogenous toxins, circulating pathogens, lipoproteins or fibrinogen—not interchangeable between devices.
  • Routes: a dedicated hemoperfusion circuit or a validated side/inline connection to CRRT, cardiopulmonary bypass (CPB), or ECMO.
  • No mandatory plasma separator: the blood cellular fraction passes through the adsorber; there is normally no planned exchange of plasma with replacement fluid.
  • Endpoint: a defined clinical response and/or target-specific biochemical response; the volume of blood pumped through a column is not equivalent to toxin clearance.
Scope of this guide: direct whole-blood sorbent cartridges. Plasma adsorption after a separator (including DPMAS) is a different modality, and ordinary dialysis membranes are not treated as direct hemoadsorption cartridges.
Clinical evidence boundary: the 2026 Surviving Sepsis Campaign suggests against blood purification techniques, including hemoperfusion, in adults with sepsis or septic shock, and separately suggests against polymyxin-B hemoperfusion. Device availability or measurable mediator removal does not establish improved patient outcomes. [1]

2. Circuit configuration and modalities

Standalone hemoperfusion

Blood is drawn from vascular access, pumped through a compatible adsorber and returned to the patient. There is no plasma-separation step and no prescribed plasma replacement.

Patient → blood pump → adsorber → air/pressure safety monitoring → patient

Use only a validated machine, tubing set, pump and anticoagulation configuration.

Combined therapy

The cartridge may be placed in a manufacturer-validated blood path associated with CRRT, intermittent HD, CPB or ECMO. Position, bypass, direction of flow, pressure and alarm logic are system-specific.

Patient ↔ extracorporeal system ↔ compatible adsorber circuit

An approved device combination does not imply all placements or line arrangements are safe.

ConfigurationPrescription considerations
Standalone direct HPSpecify blood pump, vascular access, extracorporeal volume, blood flow, hemoadsorber pressure limits, anticoagulation, fluid balance and blood return plan.
With CRRT or HDIdentify exact upstream/downstream position per manufacturer instructions; coordinate blood flow, anticoagulation, filtration and prescribed kidney replacement treatment.
With ECMO / CPBOnly a manufacturer-validated connection arrangement; confirm bypass and line-pressure conditions, no unauthorized changes to the main flow, air safety and team responsibilities.
Direct hemoadsorption vs plasma adsorptionDo not substitute a plasma-only column into a whole-blood circuit, or vice versa, without explicit model-specific authorisation.
Do not use a diagram above as a construction instruction. Device and circuit IFUs, approved tubing configurations, and local clinical-engineering checks determine the actual setup. [2] [3]

3. Core prescription parameters

Every prescription must document the exact cartridge and extracorporeal system. There is no safe universal Qb, duration, exchange interval, or anticoagulant dose for all hemoadsorption devices. [2]

ParameterRequired physician / team decisionVerification
Clinical indicationDiagnosis, severity, reason for using HA rather than standard care alone, proposed response measureCurrent evidence, local authorization and multidisciplinary approval
Cartridge modelBrand, exact model/catalogue number, target class, lot, expiry, single-use statusCurrent market-specific device IFU
Circuit / machineStandalone HP / CRRT / HD / ECMO / CPB; insertion position and compatible disposablesMachine + cartridge IFUs, engineering checks
Prescribed blood flow (Qb)Patient- and device-specific target, in mL/minAccess capacity, cartridge pressure-drop curve and alarms
Active therapy durationPlanned hours, intended number of cartridges, stopping/reassessment criteriaModel-specific upper treatment time and saturation constraints
Cartridge changeTrigger by IFU limit, pressure/clotting or predefined clinician reassessmentNot assumed from another manufacturer's lifespan
AnticoagulationAgent, patient-specific regimen, monitoring and HIT/bleeding precautionsCompatibility with the full circuit
Fluid managementPriming/rinsing, rinse-back, net balance, extracorporeal blood volumeManufacturer procedures; hemodynamic tolerance
Drug therapyAntimicrobial, anticonvulsant, anticoagulant and other relevant exposuresPharmacy review / therapeutic drug monitoring (TDM) as available
MonitoringClinical endpoints, cartridge pressure and delivered flow, platelets/coagulation, labsBaseline, on-treatment and post-treatment documentation
Device-specific numerical illustration—not a default prescription: CytoSorb's manufacturer technical guide documents a recommended blood-flow range of 150–700 mL/min in certain setups and a maximum 24-hour use per adsorber. Do not copy these numbers to other cartridges. [3]

4. Processed blood volume — Interactive calculator

This tool calculates the volume of whole blood passing through the cartridge, not plasma volume and not an adsorptive dose, target concentration reduction or drug clearance. No numerical inputs are preselected.

Processed blood (L) = Qb (mL/min) × Active circuit time (min) ÷ 1,000

Blood-processing estimator (illustrative only)

Blood processed—
Active circuit time—
Blood passing per hour—

Enter measured blood flow and duration to estimate volume.

Interpretation: Blood recirculates through the patient and cartridge. Several liters passing through the device do not mean the same volume is irreversibly cleared of a substance. Adsorption depends on concentration, kinetics, capacity, anticoagulation and delivered flow. Use manufacturer instructions and clinician-defined endpoints. [2]

5. Adsorber selection — Distinct targets

The following are examples of whole-blood-capable sorbent families, not a substitution or interchangeability table. Verify exact model, intended-use route and local regulatory status. Device claims below reflect manufacturer documentation and may exceed the strength of patient-outcome evidence.

Cartridge / manufacturerDocumented whole-blood adsorption target or purposeClinical / safety distinction
CytoSorb — CytoSorbentsBroad adsorption of selected hydrophobic middle molecules / inflammatory mediatorsCan be integrated into validated extracorporeal circuits; drug removal and cartridge change timing need separate review. [3]
HA series (HA130 / HA230 / HA330 / HA380) — JafronResin hemoperfusion; model-specific toxins and mediator classesAvoid transferring a HA-family prescription to BS330, which is a plasma-route bilirubin adsorber. [5]
MG series — Biosky / BiosunWhole-blood hemoperfusion resin for medium/large molecular substancesMG is distinct from DX plasma bilirubin adsorption. [8]
TORAYMYXIN PMX-20R / PMX-05R — Toray MedicalPolymyxin-B-immobilized endotoxin adsorptionSelective endotoxin device, with model-specific circuits; SSC 2026 suggests against routine PMX hemoperfusion for sepsis. [1] [4]
Alteco LPS Adsorber — Alteco MedicalEndotoxin adsorption using a synthetic peptide ligandManufacturer-specific priming, blood flow and treatment time; outcomes remain clinically uncertain. [6]
Seraph 100 — ExThera MedicalHeparin-mimetic affinity adsorption of certain pathogensRegulatory indications are jurisdiction-specific; U.S. historical emergency-use authorization does not equal unrestricted approval. [7]
DALI 500 / DALI 750 — Fresenius Medical CareDirect adsorption of LDL-C and Lp(a) from whole bloodLipoprotein apheresis indication, not a sepsis/cytokine device. [9]
Rheocarna — Kaneka MedixWhole-blood adsorption targeting LDL cholesterol and fibrinogenJapan-specific refractory-ulcer indication; verify local distribution/authorization. [10]
A non-specific resin cartridge, a ligand-based endotoxin sorbent, a pathogen-binding filter and a direct lipoprotein adsorber have different treatment objectives and dosing logic. No single session volume or duration applies across these categories.

6. Preparation, vascular access and anticoagulation

Pre-connection checklist

  • Confirm exact model, sterile packaging, expiry, single-use indication and IFU revision.
  • Check access patency, suitable blood-pump system, line compatibility, adsorption-column orientation and air-management configuration.
  • Document extracorporeal blood volume, priming/rinsing instructions, saline/rinse-back and potential hemodynamic effects.
  • Validate planned pressures, alarms, delivered flow monitoring and emergency bypass / blood return procedures.

Anticoagulation plan

  • Select systemic heparin, regional citrate (where permitted), or another validated protocol according to the entire circuit and patient risks.
  • Check bleeding risk, thrombocytopenia, prior HIT, liver dysfunction and citrate compatibility.
  • Monitor according to the chosen approach: ACT/aPTT or other local measures; ionized calcium / acid–base status when citrate is used.
  • Do not infer safe anticoagulation dosage from general hemoadsorption product brochures.
Critical nuance: a citrate regimen validated for one CRRT configuration may not be suitable for standalone hemoperfusion without a hemofilter or for ECMO. Apply the exact combined-system IFUs. [3] [2]

7. Clinical, technical and pharmacological monitoring

TimeRequired observations / checks
Before each sessionVital signs, hemodynamic support, indication-specific biomarkers, access; CBC/platelets, coagulation and electrolytes; medication review and baseline drug levels where relevant.
During treatment — clinicalBlood pressure, heart rate/rhythm, temperature, symptoms, vasopressor support, bleeding or hypersensitivity, net fluid balance.
During treatment — technicalDelivered Qb, circuit pressure trends and pressure drop across the cartridge, clotting/air alarms, elapsed active duration, circuit position and delivered anticoagulation.
Drug safetyReview antibiotic and antifungal dosing, antiepileptics, anticoagulants and other high-risk drugs; TDM as available. Consider removal caused by concurrent CRRT separately.
End of sessionActual treatment time and blood volume processed, cartridge changes, reason for discontinuation, blood return, adverse events and procedure-related losses.
Course / follow-upPrespecified clinical outcome (not only biomarker reduction), organ support, laboratory trends, thrombocytopenia, rebound, medication exposure, decision to continue or stop.
Drug adsorption is clinically important: published reviews show that some extracorporeal adsorbers can remove antimicrobials and other drugs. Optimize timing, dosing and laboratory monitoring with a clinical pharmacist; do not assume a given medicine is unaffected. [2] [11]

Document any interpretation challenges caused by adsorption of biomarkers as well as adsorption of the intended target. [2]

8. Clinical applications and evidence boundaries

Setting / targetHow to assess useEvidence caveat
Sepsis / septic shock — cytokines or endotoxinIdentify clinical rationale, established source control and standard sepsis bundle, clear stop endpoints and local research/approval framework.SSC 2026 suggests against blood purification including hemoperfusion and against polymyxin-B hemoperfusion; not a routine adjunct. [1]
Drug overdose or poisoningSubstance, toxicokinetics, protein binding, alternative extracorporeal removal and toxicology consultation.Only use validated sorbent/route when toxin adsorption is plausible and standard antidotes/support remain prioritized. [2]
ESRD-related symptoms / toxin adsorptionDisease-specific assessment and compatible HD+HA prescription when applicable.Evidence and local practice vary; no general survival or symptom-benefit claim. [12]
Direct lipoprotein adsorptionDocument severe lipid disease or vascular/ulcer indication and multidisciplinary assessment.Cartridge-specific indications, separate from inflammatory hemoadsorption. [9] [10]
Pathogen affinity adsorptionMicrobiology, bacteremia or infection phenotype, approval status and antimicrobial plan.Potential pathogen removal does not imply established outcome benefit or unrestricted regulatory approval. [7]
Perioperative extracorporeal supportDetermine if insertion is supported by combined circuit IFUs; monitor coagulation and drug exposure.Pilot/observational evidence does not establish routine benefit across operations. [2]
No blanket treatment schedule: do not present daily treatment, fixed cartridge change at 12 hours, an assumed volume threshold or a predetermined session count as standard across all cartridges. Repeat only after indication-specific reassessment and documented patient benefit. [2]

9. Adverse events and stopping rules

RiskPractical response
Hypotension / hemodynamic instabilityAssess blood pressure, fluid shifts, access, circuit resistance and possible acute reaction; initiate institutional emergency response.
Clotting, high pressure, air or circuit failureStop/escalate according to machine and cartridge IFUs; never override safety alarms to maintain treatment.
Thrombocytopenia, leukocyte or protein lossMonitor CBC/platelets, bleeding and other relevant tests; reassess risk–benefit, particularly with repeated use.
Hypocalcemia / citrate accumulationMonitor ionized calcium and acid–base balance where citrate is approved; clinician-led correction per protocol.
Hypersensitivity / biocompatibility reactionImmediate recognition and emergency management per institution; check device contraindications.
Drug underexposureUrgent pharmacy review, dose/timing adjustment and TDM when feasible; especially anti-infectives and other critical medicines.
No clinical benefit / objective achievedDiscontinue if predefined endpoint is met or treatment is futile; reassess on patient-centered outcomes, not only biomarker levels.
Stop or urgently reassess in severe hemodynamic compromise, severe allergic reaction, uncontrolled bleeding, unresolved air/pressure/clotting alarms, clinically important laboratory deterioration or absence of a credible therapeutic objective. Model-specific stop limits override these generic prompts.

10. Standardized hemoadsorption prescription template

Structured documentation items for the prescribing team. The blank, fillable worksheet follows in Section 11 and can be printed by itself.

Required fieldWhat must be recorded
Indication / evidenceDisease, treatment objective, care pathway and clinician authorization
Exact adsorberBrand, catalog/model number, ligand/target and regulatory/IFU confirmation
Combined circuitHP alone vs CRRT / HD / CPB / ECMO, approved connection point and machine
Access / blood flowVascular access, prescribed Qb and validated pressure/alarm limits
Planned processingActive duration, planned cartridge count and device-specific change conditions
Anticoagulation / fluidsAgent and monitoring, priming, circuit volume and return plan
Medication/TDM planDrugs at risk of adsorptive clearance, level checks and timing
Response / stop rulesClinical and technical endpoints, escalation and stopping criteria
Safety / sign-offMonitoring plan, treatment authorization, responsible clinician, signature and date

This framework is educational and cannot be used as a standing or executable medical order.

Prescription Worksheet — Complete & Print

Complete this patient-specific whole-blood hemoadsorption worksheet on screen, copy its contents, or print it separately. Blank fields are deliberate: no cartridge setting, flow, dose or anticoagulant is automatically prescribed.

Prescription fieldClinician entry / verification
Patient & clinical indication
Patient identifier / hospital record
Treatment date / time / session number
Service / responsible physician
Clinical indication and severity
Therapeutic objective and response criteria
Device, patient and circuit
Exact cartridge / adsorbent model / target
IFU revision, lot/expiry and local authorization
Treatment mode, machine and approved connection
Vascular access / circuit blood volume
Patient weight and baseline assessment
Whole-blood treatment prescription
Blood flow and active duration
Total processed blood volume (if documented)
Planned cartridge count and change criteria
Circuit pressures and alarm monitoring
Anticoagulation, medication and technical safety
Priming / rinsing / blood return / fluid balance
Anticoagulation and required monitoring
Medication review and TDM plan
Laboratory / clinical / circuit surveillance
Treatment course and authorization
Session frequency and reassessment
Stop / escalation criteria
Consent / physician validation / signature

Mandatory clinical verification: This worksheet does not select a cartridge, prescribe Qb or define anticoagulation. The signed institutional order, current manufacturer IFUs and authorisation, clinical review and local protocol take precedence. Entries stay in this local browser page and are not transmitted or stored by this document.

12. Key references and practice summary

  1. Surviving Sepsis Campaign, 2026. International Guidelines for Management of Sepsis and Septic Shock — suggests against blood purification (including hemoperfusion) and polymyxin-B hemoperfusion in adults with sepsis/septic shock. Read source.
  2. ADQI 30 Consensus, 2024. Hemoadsorption: consensus report of the 30th Acute Disease Quality Initiative workgroup. Nephrology Dialysis Transplantation 39:1945–1964. Technology, indications, uncertainty, prescribing, monitoring and risks. Read source.
  3. CytoSorbents — CytoSorb technical guide. Manufacturer-specific setup, blood flow, anticoagulation context and maximum use time. These are not general hemoadsorption settings. Read source.
  4. Toray Medical — TORAYMYXIN. Manufacturer product description and differentiated PMX models for endotoxin adsorption. Read source.
  5. Jafron Biomedical — HA series. Manufacturer product portfolio describing direct whole-blood hemoperfusion HA cartridges and separate plasma BS columns. Read source.
  6. Alteco Medical — LPS Adsorber. Direct blood endotoxin adsorption product and technical setup information. Read source.
  7. ExThera Medical — Seraph 100. Manufacturer overview of pathogen-affinity blood adsorption; regulatory status is jurisdiction-specific. Read source.
  8. Biosun — MG disposable hemoperfusion cartridge. Whole-blood MG series mechanism and advertised areas of application; distinguish from plasma DX. Read source.
  9. Fresenius Medical Care — DALI instructions for use. DALI 500/750 direct whole-blood lipoprotein adsorption; safety and approval are model-specific. Read source.
  10. Kaneka Medix — Rheocarna. Manufacturer product page for LDL-cholesterol and fibrinogen whole-blood adsorption in a Japan-specific refractory-ulcer indication. Read source.
  11. Systematic drug-clearance review, 2025. Current Knowledge on the Impact of Extracorporeal Blood Purification Devices on Drug Clearance — risk of clinically relevant drug removal and importance of TDM. Read source.
  12. International expert consensus on hemoadsorption with hemodialysis, 2026. Hemoadsorption combined with hemodialysis: a consensus statement — selected maintenance-HD configurations, evidence limitations and drug monitoring. Read source.

Essential prescribing principles

Define the clinical purpose and evidence boundary; choose the exact whole-blood adsorber and compatible circuit; document Qb, actual active duration, device-specific change limits, anticoagulation, drug/TDM plan, safety monitoring and stopping criteria. No plasma volume multiplier or generic cartridge schedule should be transferred from immunoadsorption, DFPP or plasma adsorption.

References do not replace IFUs. Manufacturer sources describe intended technical performance; regulatory approvals vary by jurisdiction and may be narrower than published applications. Follow institutional governance and qualified clinical oversight.